6 kW and 12 kW Hybrid Solar Inverter, 360 V DC Bus
En bref
- Type de produit
- Hybrid Inverter
- Puissance nominale
- 6 kW / 12 kW
- Type de batterie
- Valve-regulated lead-acid or lithium, profile set from the operation panel
- Phase
- Monophasé
Residential hybrid systems with high-voltage battery packs Available in 6 kW / 12 kW, valve-regulated lead-acid or lithium, profile set from the operation panel battery support, monophasé.
- 6 kW single-MPPT and 12 kW dual-MPPT models
- 360 V DC battery bus for lower current and thinner cabling
- Wide MPPT window from 80 VDC to 450 VDC
- Bypass function prevents backflow when running on grid
Description
The LK-H6 runs on a 360 V DC bus, which keeps DC current low for a given power level and allows thinner battery cabling than a 48 V platform. Two ratings are offered: 6 kW with a single MPPT, and 12 kW with two.
A bypass function prevents backflow when the unit is running on grid, and the working mode can be set to grid, off-grid or hybrid. Charging priority and output priority are both configurable, and the inverter supports lithium BMS communication as well as operation without a battery - useful during commissioning or where the battery arrives later.
Product highlights
- 6 kW single-MPPT and 12 kW dual-MPPT models
- 360 V DC battery bus for lower current and thinner cabling
- Wide MPPT window from 80 VDC to 450 VDC
- Bypass function prevents backflow when running on grid
- Selectable grid, off-grid and hybrid working modes
- 94% peak efficiency, 10 ms conversion time
Technical specifications
| Série | LK-H6 |
|---|---|
| Puissance nominale | 6 kW / 12 kW |
| Type de batterie | Valve-regulated lead-acid or lithium, profile set from the operation panel |
| Phase | Single phase |
| Puissance PV d'entrée max | 6000 W / 6000 W x2 |
| Plage de suivi MPPT | 80-450 VDC |
| Tension PV nominale | 360 VDC |
| Tension PV à vide max | 500 VDC |
| Courant PV d'entrée max | 27 A / 27 A x2 |
| Nombre de MPPT | 1 / 2 |
| Tension batterie | 48 VDC (42-60 VDC) |
| Courant de charge PV max | 120 A / 200 A |
| Courant de charge AC max | 80 A / 140 A |
| Tension d'entrée AC | 230 VAC, selectable 220 / 230 / 240 VAC |
| Plage d'entrée AC | 165-280 VAC or 120-280 VAC |
| Tension de sortie AC | 230 VAC, selectable 220 / 230 / 240 VAC, ±2% |
| Forme d'onde de sortie | Pure sine wave |
| Courant de sortie max | 26.1 A / 52.2 A |
| Rendement maximal | 94% |
| Consommation à vide | 1% of rated power |
| Temps de conversion | 10 ms |
| Communication | RS485 / dry contact / mobile app, WiFi or GPRS optional |
| Indice de protection | IP20 |
| Température de service | −10 to 50 °C |
| Dimensions (L×H×P) | 390x320x112 mm / 630x540x130 mm |
| Poids | 8 kg / 22 kg |
Typical applications
- Residential hybrid systems with high-voltage battery packs
- Commercial rooftop solar with self-consumption priority
- Sites where battery cable length and voltage drop are constrained
- Off-grid homes with generator top-up
- Small industrial loads with grid export