3.3 kW to 12.3 kW Hybrid Solar Inverter with Dual AC Output
En bref
- Type de produit
- Hybrid Inverter
- Puissance nominale
- 3.3 / 4.3 / 5.0 / 6.3 / 8.3 / 10.3 / 12.3 kW
- Type de batterie
- Lead-acid / lithium, charging profile set from the operation board
- Phase
- Monophasé
Homes that need to protect selected circuits during outages Available in 3.3 / 4.3 / 5.0 / 6.3 / 8.3 / 10.3 / 12.3 kW, lead-acid / lithium, charging profile set from the operation board battery support, monophasé.
- Seven models from 3.3 kW to 12.3 kW, single phase 230 V
- Second AC output rated at 30% of main output for load shedding
- Up to 2 MPPTs with 80-450 VDC tracking window
- 94% peak efficiency and 10 ms transfer time
Description
The LK-H2 adds a second AC output to the standard hybrid platform. The main output carries priority loads, while the second output can be shed automatically when battery state of charge or PV input falls below the configured threshold - useful where a site must keep refrigeration or lighting running but can afford to drop air conditioning.
Models run from 3.3 kW to 12.3 kW on a 24 V or 48 V battery bus, with up to two MPPTs on the larger units. The second output is rated at 30% of the main output. As with the rest of the range, grid-tied, off-grid and hybrid modes are selectable, and the unit supports lithium BMS communication and battery-less operation.
Product highlights
- Seven models from 3.3 kW to 12.3 kW, single phase 230 V
- Second AC output rated at 30% of main output for load shedding
- Up to 2 MPPTs with 80-450 VDC tracking window
- 94% peak efficiency and 10 ms transfer time
- Adjustable grid-feed current, output priority and charge priority
- Lithium BMS communication, battery-less operation supported
Technical specifications
| Série | LK-H2 |
|---|---|
| Puissance nominale | 3.3 / 4.3 / 5.0 / 6.3 / 8.3 / 10.3 / 12.3 kW |
| Type de batterie | Lead-acid / lithium, charging profile set from the operation board |
| Phase | Single phase |
| Puissance de seconde sortie | 990 W / 1290 W / 1500 W / 1890 W / 2480 W / 3.09 kW / 3.69 kW |
| Puissance PV d'entrée max | 5.0 kW to 7.0 kW, or 4.5 kW x2 / 6.0 kW x2 |
| Plage de suivi MPPT | 40-450 VDC (24 V models) / 80-450 VDC (48 V models) |
| Tension PV nominale | 240 VDC / 280 VDC |
| Tension PV à vide max | 500 VDC |
| Courant PV d'entrée max | 18 A to 27 A, or 18 A x2 / 22 A x2 / 27 A x2 |
| Nombre de MPPT | 1 or 2, by model |
| Tension batterie | 24 VDC (21-30 VDC) or 48 VDC (42-60 VDC) |
| Courant de charge PV max | 100 A to 200 A, by model |
| Courant de charge AC max | 80 A to 140 A, by model |
| Tension d'entrée AC | 230 VAC, selectable 220 / 230 / 240 VAC |
| Plage d'entrée AC | 165-280 VAC or 120-280 VAC |
| Tension de sortie AC | 230 VAC, selectable 220 / 230 / 240 VAC, ±2% |
| Forme d'onde de sortie | Pure sine wave |
| Courant de sortie max | 14.3 A to 53.5 A, by model |
| Rendement maximal | 94% |
| Temps de transfert | 10 ms |
| Communication | RS485 / mobile app / WiFi monitoring, GPRS optional |
| Indice de protection | IP20 |
| Température de service | −10 to 50 °C |
| Dimensions (L×H×P) | 325x275x102 mm to 630x540x130 mm, by model |
| Poids | 5.5 kg to 22 kg, by model |
Typical applications
- Homes that need to protect selected circuits during outages
- Small hotels and guesthouses with split critical and non-critical loads
- Shops running refrigeration plus lighting on one battery bank
- Offices with priority IT loads and deferrable HVAC
- Off-grid villas with generator-assisted charging