10 kW and 12 kW Parallel Hybrid Solar Inverter, 200-240 V Output
En bref
- Type de produit
- Hybrid Inverter
- Puissance nominale
- 10 kW / 12 kW
- Type de batterie
- Lead-acid / lithium, charging profile set from the operation board
- Phase
- Single phase, three-phase capable when paralleled
Whole-house backup for large villas and estates Available in 10 kW / 12 kW, lead-acid / lithium, charging profile set from the operation board battery support, single phase, three-phase capable when paralleled.
- 10 kW and 12 kW models, single phase, 200-240 VAC selectable output
- Parallel up to 6 units on one phase, or combine into three-phase
- 2x rated peak power for pumps, compressors and other inductive loads
- Dual MPPT inputs, 125-425 VDC tracking range, 500 VDC maximum
Description
The LK-H5 is built for larger single-phase systems. Two ratings - 10 kW and 12 kW - can be paralleled up to six units on one phase, or combined into a three-phase bank with a consistent power board and address setting. Output voltage is selectable across 200 / 208 / 220 / 230 / 240 VAC, which covers both 220 V and 240 V markets without a transformer.
Peak output is twice the rated power, aimed at inductive loads such as pumps and compressors with a unity-power-factor starting surge. The unit runs solar and mains simultaneously, allows input and charging current to be trimmed to the actual load, and includes lithium battery activation plus BMS communication.
Product highlights
- 10 kW and 12 kW models, single phase, 200-240 VAC selectable output
- Parallel up to 6 units on one phase, or combine into three-phase
- 2x rated peak power for pumps, compressors and other inductive loads
- Dual MPPT inputs, 125-425 VDC tracking range, 500 VDC maximum
- Simultaneous solar and mains charging with adjustable current limits
- 92% peak efficiency, 10 ms transfer time, USB / RS485 / dry contact
Technical specifications
| Série | LK-H5 |
|---|---|
| Puissance nominale | 10 kW / 12 kW |
| Type de batterie | Lead-acid / lithium, charging profile set from the operation board |
| Phase | Single phase, three-phase capable when paralleled |
| Puissance PV d'entrée max | 5500 W x2 / 6500 W x2 |
| Plage de suivi MPPT | 125-425 VDC |
| Tension PV nominale | 360 VDC |
| Tension PV à vide max | 500 VDC |
| Courant PV d'entrée max | 32 A x2 |
| Nombre de MPPT | 2 |
| Tension batterie | 48 VDC (42-60 VDC) |
| Courant de charge PV max | 200 A / 220 A |
| Courant de charge AC max | 120 A / 140 A |
| Tension d'entrée AC | 200 / 208 / 220 / 230 / 240 VAC |
| Plage d'entrée AC | 170-280 VAC or 90-280 VAC |
| Tension de sortie AC | 200 / 208 / 220 / 230 / 240 VAC, ±2% |
| Forme d'onde de sortie | Pure sine wave |
| Courant de sortie max | 43.5 A / 52.2 A |
| Capacité de mise en parallèle | Up to 6 units, single or three phase |
| Rendement maximal | 92% |
| Consommation à vide | 1% of rated power |
| Temps de transfert | 10 ms |
| Affichage | LCD + LED |
| Communication | USB / RS485 / dry contact / mobile app, WiFi or GPRS optional |
| Indice de protection | IP20 |
| Température de service | −10 to 50 °C |
| Dimensions (L×H×P) | 610x445.5x136.5 mm |
| Poids | 21 kg / 21.5 kg |
Typical applications
- Whole-house backup for large villas and estates
- Small commercial and agricultural sites with pump loads
- Three-phase installations built from single-phase modules
- Mini-grids and community power schemes
- Telecom shelters and remote base stations