700 W to 40 kW Low-Frequency Off-Grid Inverter, 12 V to 384 V DC
Remote homes and cabins beyond the distribution network Available in 0.7 / 1.0 / 1.5 / 2.0 / 3.0 / 3.5 / 4.0 / 5.0 / 6.0 / 7.0 / 8.0 / 10 / 12 / 15 / 20 / 25 / 30 / 40 kW, lead-acid, lithium or custom battery support, single phase.
- 0.7 / 1.0 / 1.5 / 2.0 / 3.0 / 3.5 / 4.0 / 5.0 / 6.0 / 7.0 / 8.0 / 10 / 12 / 15 / 20 / 25 / 30 / 40 kW rated capacity
- Lead-acid, lithium or custom battery support
- Single phase configuration
- OEM, ODM and private label
Description
Product highlights
- 0.7 / 1.0 / 1.5 / 2.0 / 3.0 / 3.5 / 4.0 / 5.0 / 6.0 / 7.0 / 8.0 / 10 / 12 / 15 / 20 / 25 / 30 / 40 kW rated capacity
- Lead-acid, lithium or custom battery support
- Single phase configuration
- OEM, ODM and private label
- Factory direct supply
- Export documentation support
Technical specifications
| Rated power | 0.7 / 1.0 / 1.5 / 2.0 / 3.0 / 3.5 / 4.0 / 5.0 / 6.0 / 7.0 / 8.0 / 10 / 12 / 15 / 20 / 25 / 30 / 40 kW |
|---|---|
| Input voltage range | On request |
| MPPT channels | — |
| Battery type | Lead-acid, lithium or custom |
| Max charge current | On request |
| Efficiency | On request |
| Communication | On request |
| Protection rating | On request |
| Dimensions | On request |
| Weight | On request |
Typical applications
- Remote homes and cabins beyond the distribution network
- Telecom, monitoring and security cabinets
- Rural clinics, schools and community buildings
- Sites combining PV arrays with lead-acid or lithium banks
Related products
Description
The LK-L3 is the widest low-frequency family in the programme: eighteen models from 700 W to 40 kW, spanning 12 V, 24 V, 48 V, 96 V, 192 V, 240 V and 384 V battery banks. That spread lets a single product family serve everything from a 700 W rural cabin to a 40 kW three-phase-site inverter without changing supplier.
Above 3.5 kW the units move to 48 V and higher buses, with MPPT input power scaling to 22.4 kW x2 on the 40 kW model. All models deliver pure sine wave at 220 / 230 / 240 VAC with > 85% conversion efficiency, and accept diesel or petrol generator input.
Product highlights
- Eighteen models from 700 W to 40 kW
- Battery banks from 12 VDC up to 384 VDC
- Up to 22.4 kW x2 PV input on the 40 kW model
- Toroidal transformer, pure sine wave, > 85% efficiency
- Generator compatible for weak-grid and off-grid sites
- Optional built-in MPPT or PWM solar controller
Technical specifications
| Rated power | 0.7 / 1.0 / 1.5 / 2.0 / 3.0 / 3.5 / 4.0 / 5.0 / 6.0 / 7.0 / 8.0 / 10 / 12 / 15 / 20 / 25 / 30 / 40 kW |
|---|---|
| Battery type | Lead-acid, lithium or custom |
| Phase | Single phase |
| Topology | Low frequency, toroidal transformer |
| Optional MPPT rated current | 30 A / 60 A on 12-48 V models; 100 A on 96 V and above |
| Max PV input power | 12 V 420 W / 24 V 840 W / 48 V 1680 W; 24 V 1680 W / 48 V 3360 W / 96 V 6720 W; 48 V 5600 W / 96 V 6720 W; up to 240 V 14 kW x2 / 384 V 22.4 kW x2 |
| Max PV open-circuit voltage | 120 VDC (12/24 V) / 180 VDC (48 V) / 300 VDC (96 V) / 450 VDC (192 V) / 500 VDC (240 V) / 800 VDC (384 V) |
| MPPT tracking range | 12 V 15-80 V / 24 V 30-100 V / 48 V 60-140 V / 96 V 120-240 V / 192 V 240-380 V / 240 V 300-400 V / 384 V 480-640 V |
| Battery voltage | 12 / 24 / 48 / 96 / 192 / 240 / 384 VDC, by model |
| Battery voltage range | 10.5-15 V / 21-30 V / 42-60 V / 84-120 V / 168-240 V / 210-300 V / 336-480 V |
| AC input voltage | 220 VAC, selectable 230 / 240 VAC |
| AC input range | 160-275 VAC (220 V) / 170-285 VAC (230 V) / 180-295 VAC (240 V) |
| AC output voltage | 220 / 230 / 240 VAC ±2% |
| Output waveform | Pure sine wave |
| Conversion efficiency | > 85% |
| No-load consumption | 1% of rated power |
| Display | LCD |
| Communication | RS485 / app, WiFi or GPRS monitoring optional |
| Protection rating | IP20 |
| Operating temperature | −15 to 40 °C |
| Dimensions (LxWxH) | 340x165x283 mm to 721x400x1002 mm, by model |
| Weight | 9.5 kg to 192 kg, by model |
Typical applications
- Village electrification and mini-grids
- Large off-grid homes, lodges and farms
- Industrial sites with 192 V or 384 V DC banks
- Water pumping and irrigation schemes
- Telecom, mining and construction camps



