1 kW to 12.3 kW Hybrid Solar Inverter with Built-in MPPT Charger
Residential solar self-consumption with battery backup Available in 1.0 / 1.3 / 1.8 / 1.8 / 2.3 / 3.3 / 4.3 / 5.0 / 6.3 / 8.3 / 10.3 / 12.3 kW, lead-acid / lithium, charging profile set from the operation board battery support, single phase.
- 1.0 / 1.3 / 1.8 / 1.8 / 2.3 / 3.3 / 4.3 / 5.0 / 6.3 / 8.3 / 10.3 / 12.3 kW rated capacity
- Lead-acid / lithium, charging profile set from the operation board battery support
- Single phase configuration
- OEM, ODM and private label
Description
Product highlights
- 1.0 / 1.3 / 1.8 / 1.8 / 2.3 / 3.3 / 4.3 / 5.0 / 6.3 / 8.3 / 10.3 / 12.3 kW rated capacity
- Lead-acid / lithium, charging profile set from the operation board battery support
- Single phase configuration
- OEM, ODM and private label
- Factory direct supply
- Export documentation support
Technical specifications
| Rated power | 1.0 / 1.3 / 1.8 / 1.8 / 2.3 / 3.3 / 4.3 / 5.0 / 6.3 / 8.3 / 10.3 / 12.3 kW |
|---|---|
| Input voltage range | On request |
| MPPT channels | — |
| Battery type | Lead-acid / lithium, charging profile set from the operation board |
| Max charge current | On request |
| Efficiency | On request |
| Communication | On request |
| Protection rating | On request |
| Dimensions | On request |
| Weight | On request |
Typical applications
- Residential solar self-consumption with battery backup
- Small commercial and retail sites on weak grids
- Single or three-phase household distribution boards
- Generator-assisted backup for extended outages
Related products
Description
The LK-H1 is a wall-mounted single-phase hybrid inverter family covering 1 kW to 12.3 kW in twelve steps. It combines a high-frequency inverter, a wide-range MPPT solar charger and a multi-stage mains charger in one enclosure, so a single unit can run a load, charge a battery bank and export surplus solar to the grid.
The platform accepts lead-acid, gel and lithium packs on a 24 V or 48 V bus. A full digital control stage allows bidirectional energy flow, which means solar and mains can charge the battery at the same time while the inverter feeds the load. Nine working parameters - including grid-current limit, output priority and charge priority - are set from the front panel or over RS485, so the same hardware can be configured for grid-tied, off-grid or hybrid duty.
Product highlights
- Twelve models from 1 kW to 12.3 kW, single phase 230 V
- Wide MPPT window from 40 VDC (24 V models) or 80 VDC (48 V models)
- Selectable grid-tied, off-grid and hybrid working modes
- Adjustable grid-feed current, output priority and charge priority
- Lithium battery BMS communication and battery-less operation
- Peak conversion efficiency 94%, transfer time 10 ms
Technical specifications
| Rated power | 1.0 / 1.3 / 1.8 / 1.8 / 2.3 / 3.3 / 4.3 / 5.0 / 6.3 / 8.3 / 10.3 / 12.3 kW |
|---|---|
| Battery type | Lead-acid / lithium, charging profile set from the operation board |
| Phase | Single phase |
| Max PV input power | 1.5 kW to 6.0 kW x2 (by model) |
| MPPT tracking range | 30-240 VDC (24 V models) / 40-350 VDC / 40-450 VDC (48 V models) |
| Rated PV voltage | 180 VDC (24 V models) / 240 VDC / 280 VDC |
| Max PV open-circuit voltage | 300 VDC (24 V models) / 400 VDC / 500 VDC |
| Max PV input current | 13 A to 27 A, or 18 A x2 / 22 A x2 / 27 A x2 |
| MPPT channels | 1 or 2, by model |
| Battery voltage | 24 VDC (21-30 VDC) or 48 VDC (42-60 VDC) |
| Max PV charging current | 60 A to 200 A, by model |
| Max AC charging current | 40 A to 140 A, by model |
| AC input voltage | 230 VAC, selectable 220 / 230 / 240 VAC |
| AC input range | 165-280 VAC or 120-280 VAC |
| AC input frequency | 50 / 60 Hz, 45-55 Hz or 55-65 Hz |
| AC output voltage | 230 VAC, selectable 220 / 230 / 240 VAC, ±2% |
| Output waveform | Pure sine wave |
| Max output current | 4.3 A to 53.5 A, by model |
| Peak efficiency | 94% |
| No-load consumption | 1% of rated power |
| Transfer time | 10 ms |
| Display | LCD + LED |
| Communication | RS485 / mobile app / WiFi monitoring, GPRS optional |
| Protection rating | IP20 |
| Operating temperature | −10 to 50 °C |
| Dimensions (WxHxD) | 265x231x91 mm to 630x540x130 mm, by model |
| Weight | 3 kg to 22 kg, by model |
Typical applications
- Residential rooftop solar with battery backup
- Small shops, clinics and offices on weak or unstable grids
- Off-grid homes and rural electrification projects
- Telecom and security sites that need 24 h DC-backed AC supply
- Retrofit of existing lead-acid battery banks with solar charging



