Dry-Type Transformers
Cast-resin SC(B)10–18, silicone-rubber SJC B14/18 and amorphous-alloy SCBH15/17/19, 30–2500 kVA, 10 kV class.
Typical applications
Where this equipment fits
A defined equipment scope, a named manufacturing partner and a compliance route stated in the quotation.
Indoor installations where oil is not permitted.
Commercial buildings with cast-resin transformers.
Data and telecom rooms requiring dry-type units.
Industrial plants using silicone-rubber or amorphous-alloy dry-type transformers.
Model range
Dry-type transformer range
Confirm the final rating against the project datasheet before order.
| Series | Type | Rating | HV | LV | Vector group | Impedance |
|---|---|---|---|---|---|---|
| SC(B)10/11 | Cast resin | 30–2500 kVA | 6–11 kV | 0.4 kV | Yyn0 / Dyn11 | 4% / 6% |
| SC(B)12/13/14/18 | Cast resin | 30–2500 kVA | 10 kV | 0.4 kV | Dyn11 | 4% / 6% |
| SJC B14/18 | Silicone rubber | 30–2500 kVA | 10–35 kV | 0.4–10 kV | Per design | Per design |
| SCBH15/17/19 | Amorphous alloy | 50–2500 kVA | 10 kV | 0.4 kV | Dyn11 | 4% / 6% |
Technical parameters
Technical parameters
Technical parameters
Technical parameters
| Parameter | Value |
|---|---|
| Capacity | 30–2500 kVA |
| High voltage | 6 / 6.3 / 6.6 / 10 / 10.5 / 11 kV |
| Low voltage | 0.4 kV |
| Tap range | ±5% or ±2×2.5% |
| No-load loss | 190–3600 W |
| Load loss at 75°C | 620–14,990 W |
| Load loss at 120°C | 710–17,170 W |
| No-load current | 2.1–0.7% |
| Impedance | 4% at ≤630 kVA; 6% at ≥800 kVA |
| Efficiency class | SC(B)12 = 3; SC(B)14 = 2; SC(B)18 = 1 |
Efficiency classes refer to the SC(B)12/13/14/18 series.
Optional configuration
Options confirmed at quotation
The list below is the configuration scope for this family. Project-specific requirements are confirmed in writing.
- Cast-resin SC(B)10/11
- Cast-resin SC(B)12/13/14/18
- Silicone-rubber SJC B14/18
- Amorphous-alloy SCBH15/17/19
- Yyn0 or Dyn11 vector group
- 4% impedance up to 630 kVA
- 6% impedance from 800 kVA
- 10–35 kV high voltage for SJC B14/18
Testing and compliance
Reports named, limits stated
GB type test reports are held for SC(B) dry-type transformers, SCBH19 amorphous dry-type transformers and SJC B14 silicone-rubber dry-type transformers.
GB type test report scope
- SC(B) dry-type
- SCBH19 amorphous dry-type
- SJC B14 silicone-rubber dry-type
Manufacturing partner
Built with a transformer specialist
Manufacturing partner: Guangdong Yuete Transformer Co., Ltd., based in Shishan, Nanhai, Foshan and affiliated with Guangdong Yuete Electric Power Group. Transformer operations began in 2009, with four production bases in Foshan and Jiangmen. The 35 kV / 31.5 MVA on-load tap-changing oil-immersed power transformer GB type test report was obtained in January 2026.
- Started
- 2009
- Production bases
- 4
- GB type test rating
- 31.5 MVA
Manufacturing is carried out by Guangdong Yuete Transformer Co., Ltd.; LONCOTEK coordinates specification, inspection and documentation. Lead time confirmed at order.