1 kW to 6 kW Split-Phase Low-Frequency Inverter, 110 / 220 V Output
Residential solar self-consumption with battery backup Available in 1.0 / 1.5 / 2.0 / 3.0 / 4.0 / 5.0 / 6.0 kW, — battery support, split phase, l1-n / l2-n 110 vac, l1-l2 220 vac.
- 1.0 / 1.5 / 2.0 / 3.0 / 4.0 / 5.0 / 6.0 kW rated capacity
- — battery support
- Split phase, L1-N / L2-N 110 VAC, L1-L2 220 VAC configuration
- OEM, ODM and private label
Description
Product highlights
- 1.0 / 1.5 / 2.0 / 3.0 / 4.0 / 5.0 / 6.0 kW rated capacity
- — battery support
- Split phase, L1-N / L2-N 110 VAC, L1-L2 220 VAC configuration
- OEM, ODM and private label
- Factory direct supply
- Export documentation support
Technical specifications
| Potencia nominal | 1.0 / 1.5 / 2.0 / 3.0 / 4.0 / 5.0 / 6.0 kW |
|---|---|
| Rango de tensión de entrada | A solicitud |
| Canales MPPT | — |
| Tipo de batería | — |
| Corriente de carga máxima | A solicitud |
| Eficiencia | A solicitud |
| Comunicación | A solicitud |
| Grado de protección | A solicitud |
| Dimensiones | A solicitud |
| Peso | A solicitud |
Typical applications
- Residential solar self-consumption with battery backup
- Small commercial and retail sites on weak grids
- Single or three-phase household distribution boards
- Generator-assisted backup for extended outages
Related products
Description
The LK-L5 produces a split-phase output from a single chassis: 110 VAC from either leg to neutral, and 220 VAC leg to leg. That is what a North American panel expects, and it removes the need for a separate step-up transformer in a residential install.
Seven models cover 1 kW to 6 kW on 12, 24 or 48 V batteries. The toroidal transformer gives > 85% conversion efficiency and a 4 ms transfer time, and the charger accepts a wide 70-275 VAC input so it can work from a generator as well as the grid. Three working modes - mains priority, inverter priority and energy-saving - are selectable.
Product highlights
- Split-phase output: 110 VAC to neutral, 220 VAC leg to leg
- Seven models from 1 kW to 6 kW, 12 / 24 / 48 V battery
- Toroidal transformer, > 85% conversion efficiency, 4 ms transfer
- Wide 70-275 VAC AC input range for grid or generator
- Mains priority, inverter priority and energy-saving modes
- Adjustable mains charging current to match battery capacity
Technical specifications
| Rated power | 1.0 / 1.5 / 2.0 / 3.0 / 4.0 / 5.0 / 6.0 kW |
|---|---|
| Phase | Split phase, L1-N / L2-N 110 VAC, L1-L2 220 VAC |
| Battery voltage | 12 / 24 / 48 VDC, 24 / 48 VDC, 48 VDC by model |
| Installation | Wall mounted |
| MPPT charging current | 30-60 A / 60-100 A, by model |
| PV array maximum power | 12 V 420-840 W / 24 V 840-1680 W / 48 V 1680-3360 W; 24 V 1680-2800 W / 48 V 3360-5600 W |
| Max PV open-circuit voltage | 120 VDC (12/24 V) / 180 VDC (48 V) |
| MPPT tracking range | 12 V 15-80 V / 24 V 30-100 V / 48 V 60-140 V |
| Standby loss | < 3 W |
| Max conversion efficiency | > 95% |
| AC input range | 80-133 / 90-138 / 198-242 / 207-253 / 216-264 VAC; 70-275 / 80-285 / 90-295 VAC for 220-240 V models |
| AC input frequency | 45-55 Hz or 55-65 Hz |
| Max AC charging current | 0-30 A, model dependent |
| AC output voltage | 105 / 110 / 115 / 120 VAC ±2% (L-N); 220 / 230 / 240 VAC ±2% (L-L) |
| Output waveform | Pure sine wave |
| Efficiency (AC mode) | min 99% |
| Transfer time | max 4 ms |
| Display | LCD |
| Communication | RS485 / app / WiFi / GPRS data collector, optional |
| Protection rating | IP20 |
| Operating temperature | −10 to 40 °C |
| Dimensions (WxHxD) | 500x300x140 mm / 530x335x150 mm |
| Weight | 13 kg to 26 kg, by model |
Typical applications
- North American residential backup panels
- Off-grid homes needing both 110 V and 220 V circuits
- Cabins and workshops with 240 V welders or pumps
- Small commercial buildings on split-phase service
- Generator-backed remote properties